W-350 Revision 3.10 08/09 Release H: Updates 250B to latest release to include Bin Quantity option on main screen. Release F: Allows FRM and FRR test types to be binned (not go to bin 0 on Dead). Release B: Fixed a problem where some 250B cards coupled with certain crystals would report the wrong amplitude value for RF In at low amplitude levels (below -100 dBm). 1. Added a contact cycle counter and alarm for the W-350D. W-350 Revision 3.06 10/08 1. Fixed a bug that could cause good parts to be binned as failures immediately following a bin limit message. W-350 Revision 3.05 08/08 1) No user significant changes. W-350 Revision 3.04 08/08 1) Latest 250B. W-350 Revision 3.03 03/08 1) No user significant changes. W-350 Revision 3.02 09/07 1) In manual or automatic mode system would generate application error when attempting to pause or feed crystal. This was specific to a 350A or 350B system only. W-350 Revision 3.01 06/07 1) If the gate is unable to move to pass or fail position, the soleniods will be disabled and the user can either cancel or retry to move to position. W-350 Revision 3.00 02/07 1) On W-350D with sorter option installed, if a part is not detected at the stage position (e.g. fed upside down), part is now binned in the retry bin (bin 0). W-350 Revision 2.91 08/06 1) W-350A and W-350B machines running software revision 2.80 through 2.90 need this revision. It fixes a bug that affects IR measurement. Revisions 2.80 through 2.90 could report the wrong IR value on these two machine configurations. All other systems are fine. W-350 Revision 2.90 06/06 1) Added support for System Halt Sensor. 2) Increment bin in 350D checkout is now working. W-350 Revision 2.82 05/06 1) Filename shown on sorter now always matches 250B. W-350 Revision 2.81 04/06 1) Implemented a delay at stage to stop some parts from getting stuck in the stage position on the 350D. W-350 Revision 2.80 02/06 1) Added support for oscillators (W-280A). 2) Simplified IR calibration. 3) Added an ini file entry for delay in the 350D to allow contacts to retract before turning on air. Reduces contact wear. W-350 Revision 2.73 10/05 1) On 350D, no longer operating stage and hold solenoids at the same time to prevent some SMD parts from double feeding. W-350 Revision 2.72 10/05 1) No user significant change. W-350 Revision 2.71 10/05 1) If the external frequency standard check fails a dialog message is displayed indicating problem and allowing a retry. W-350 Revision 2.70 08/05 1) Can now run Feed Continuously in checkout without parts. 2) Removed port select from calibration. W-350 Revision 2.61 08/05 1) No user significant change. W-350 Revision 2.60 08/05 1) On 350D, added ini file setting for Stage solenoid polarity.