NOTE: Recommend upgrade if running revision 8.00 through 8.05. 2200 Revision 8.60 02/22 Release B: Improved RTD measurements for better 2220 measurements. 1. If CSV was selected for the export format for an Excel export, the drop box would not indicate it when the print configuration dialog was shown. Corrected that. 2. If the pathname was not standard, the pathname was not being displayed in the CSV format for Excel export. Corrected that. 3. In the CSV format for Excel export, changed the behavior so that eight rows are always output even on a system with a fewer number of rows. That way the number of rows in the header is always the same. 4. A change was made to the Excel Export reports so that the rows shown in the header do not have a blank line between them anymore. 2200 Revision 8.50 10/22 Release B: Improve the output power level when using "into RR". 1. Improved frequency measurements in some cases where ambient temperature is changing. 2200 Revision 8.40 05/22 Release C: Corrects an issue with the 250B-2 on some PCIe slots on some newer motherboards. Release B: Corrects a problem in the 250B when using all 30 test types and adding a graph display. 1. Since revision 7.00 when measuring F/R Only, the number of averages were set to 10 regardless of the any sweep settings. Corrected this. This is important for high time-constant parts measuring F/R Only or for systems with the faster 250B-2 that needed to reduce measurement noise. 2200 Revision 8.31 02/22 1. Solves a problem on some systems reporting the following errors: A. The query cannot be completed. Either the size of the query result is larger than the maximum size of a database (2 GB), or there is not enough temporary storage space on the disk to store the query result. Driver's SQLSetConnectAttr failed B. Attempt to Compact Database Failed Unknown error 0x800ADC6F C. Internal Application Error 2200 Revision 8.30 01/22 1. Since revision 8.03, the display was not being updated properly when the MAXIMIZE or RESTORE buttons in the frame were selected. Corrected this. 2. Changed the 82 Position Test Wheel from the last revision to an 83 Position Test Wheel. 3. Added 20 Position Test Wheel. 2200 Revision 8.21 01/22 1. Revision 8.20 had a bug when exporting XLS format. Corrected that. 2. New CSV mode now works with Run Name + Report Name selected. 3. Added 82 Position Test Wheel. 2200 Revision 8.20 12/21 1. Exporting using XLS format is done via Crystal Reports. This limits the number of rows to 65,536. Starting with this revision, if reports starting with "Excel Export" are set to export to CSV mode, it will generate a CSV format that matches the XLS reports and allows an unlimited number of rows. This changes the output format of these reports when selecting CSV mode, but the previous format was not really usable. 2200 Revision 8.10 12/21 1. Corrects an issue that could cause the application to close without warning during a run. 2200 Revision 8.05 10/21 RELEASE B: Upgrade necessary for all W-2220 systems running revision 8.00 or higher. Corrects an issue with C0 measurements. 1. No user significant change. 2200 Revision 8.04 09/21 Release B: Since revision 8.00, for fixtures that require a separate C0 calibration in addition to standard calibration, a bug prevented the calibration data from being loaded. When attempting to measure, an error message would be displayed indicating that a wider frequency calibration was required for C0. This includes most low frequency fixtures such as the 1000K Ohm. Also corrects an issue with some of the 250B INI file settings when starting with no INI file. 1. Since revision 7.00, if an external standard error was detected, the error was not cleared. The only option was to switch to internal standard, exit the 2200 software, then restart and select external standard. This software will clear the captured error condition. Only a new or recurring error will generate the message again. 2200 Revision 8.03 07/21 1. The last revision could leave some fields on the main view in the wrong location at startup. 2200 Revision 8.02 07/21 1. Improved the way the resize function works on the main view. 2. Fixed some memory leaks. This could have caused trouble when the application was left running for a long time. 2200 Revision 8.01 07/21 1. Prior to this revision, if the W-2200 window was minimized when the application was closed, upon restarting the application, the window would not be visible and could not be made visible. Corrected this. 2200 Revision 8.00 06/21 NOTE: Recommended all W-2220 systems upgrade to this revision. Measurement improvement to TMX measurements and orbits tests. 1. Improved the TMX measurement, especially at lower temperatures. 2. Enhanced the Show RTD/TMX dialog to allow measurements for each to be enabled or disabled. 2200 Revision 7.90 04/21 1. Manuals are now accessible in the Help menu. 2. Made significant improvements to the throughput of a dual chamber system. 3. It is possible this revision will make some throughput improvements on certain single chamber systems and setups. 2200 Revision 7.80 04/21 1. Corrects a bug that could cause the 250B Measure FR Only measurement to hang. This was first observed on a dual chamber system. 2200 Revision 7.73 03/21 RELEASE C: Includes a new 250B DLL to address a new motherboard. RELEASE B: Includes a new 250B to correct the handling of TMXR and TMXP when the 250B is running as part of a temperature system but the measurement is made using the 250B. 1. Corrected an issue since revision 7.70 that could cause RTD and TMX measurements to not occur. 2200 Revision 7.72 11/20 Release C: Updated RTDTMXMgr revision to support new motherboards. Release B: Updated the 250B revision to support newer motherboards and to prevent a rare lockup. 1. Modified the routine for editing plots to allow time on the x-axis if the database is empty. Previously, there had to be valid timestamps on the data in the database to enable that option. 2200 Revision 7.71 11/20 1. On the W-2220, if the card is a 250B-2 or 250C-2, measurements may be improved if the external standard is NOT connected. Beginning with this revision, a message box will inform the operator if the external standard is connected at the start of the run. 2200 Revision 7.70 09/20 1. Corrected an error on the top of the graphs when serial numbers are used. Previous versions did not display correctly. 2. Added support for RTD@P and RTDT@P test types in the W-2220. 3. Corrected the value for RTD in setup file parameters when TMX is also being measured. 2200 Revision 7.64 05/20 1. In the revision 7.63, RTD and TMXR test types were always shown in Ohms instead of the selected units which could be KOhms. This could cause limits to be exceeded. 2200 Revision 7.63 03/20 1. Improved RTD and TMX measurements on the W-2220 systems by preventing a timeout that generates a DMM Error. 2. This release includes a new revision of the 250B that will skip the sweep when the measured C0 is out of the valid range (short or open). 2200 Revision 7.62 03/20 1. Now handles some older RUN that had missing information, possibly from being corrupted, so that no error occurs when trying to update them or correct Windows 10 paths. 2. In version 7.30, a change was made that caused the test type STATUS not to get set correctly. That has been corrected. 3. In version 7.30, post-processed test types such as F/T that were not measured at every temperature could show an invalid value in the report and fail a limit if one was set. This has been corrected. 2200 Revision 7.61 02/20 1. When the Select Displays interface was rewritten in revision 7.60, an update could add another unintended display. This revision corrects that condition. 2. Since revision 7.30, wheel speed has not been being set correctly. 3. First revision to support the ability to override spur sweep averages. 4. Includes a new revision of the 250B that will not shut down during a temperature run if all 30 test types are defined. 2200 Revision 7.60 09/19 Release B: Brings in latest 250B to resolve a problem with it closing down when measuring a dead part in some cases. 1. Changed the way the display boxes are configured. Removed individual menu entries and all selection is now done through the Select Displays menu item. 2. Made changes to database settings to attempt to eliminate an out of memory error that was reported. 3. No longer initializing the chamber speed or number of positions when the application starts up. 4. The F/T test type now properly handles dead measurements and situations where curve-fit data is not available. 5. When running on Windows 10, export file paths are now checked for old XP paths and will be updated if OK is selected. 6. Added support for new combo software keys that work for both XP and Windows 10. 2200 Revision 7.50 08/19 1. Added FLTRG test type support. 2. Fixed a bug with overriding spur sweep averages. 3. Corrects a problem that could cause the 250B to close and generate an RPC error if measuring DLD and the C0 measurement was outside the min/max range (open, for example). 2200 Revision 7.40 08/19 1. Fixed a problem when previewing a report from the second chamber in a dual chamber system. 2. Fixed an intermittent bug with printing that would generate an RPC failure. 2200 Revision 7.30 03/19 Release B: Resolves a problem with DLD data export that occurred in revision 7.00. 1. Corrected an error in the print manager interface. 2. Addressed an issue which could cause the software to appear to be hung up after calibrating RTDs (W-2220). 3. Improved operator messages when attempting to open files that may not actually exist. 4. Allowed file dialogs to be resized again. 2200 Revision 7.20 03/19 1. Fixed a bug that would cause a setup file parameter print failure if all 30 test types were defined. 2. Includes latest 250B which significantly improves Measured FL results in some situations. Highly recommended for systems with 250B-2 and 250C-2 cards. 2200 Revision 7.10 02/19 Release B: Latest 250B significantly improves Measured FL results in some situations. Highly recommended for systems with 250B-2 and 250C-2 cards. 1. Includes latest 250B revision necessary to insure correct measurements for FL when using Crystal Data or FR Only. All versions since 7.00 should upgrade to 7.10. 2200 Revision 7.03 01/19 1. Solved a problem with measuring using physical load that occurred in revision 7.00. 2. Solved a problem since revision 7.00 with runs that have different setup files that change whether the run is measuring FR or FL over temperature. 2200 Revision 7.02 09/18 1. No user significant change. 2200 Revision 7.01 09/18 1. Added support for dual chambers in Windows 10 version. 2. Removed a delay during TMX testing that was in revision 7.00 that added time at each board change. 2200 Revision 7.00 09/18 1. Support for Windows 10. 2200 Revision 6.92 04/18 1. Corrected a problem that could occur on the first temperature table line if the chamber was already at a set temperature when the run started or if the chamber was in shut down mode when the run was started. This problem would send the chamber to the wrong initial temperature in some cases. 2200 Revision 6.91 03/18 1. Support LAN connection of the DMM in W-2220 systems using a new version of the RTD/TMX manager. 2. Support faster and newer DMMs (Keysight 34461A and 34465A) for W-2220 via a new version of the RTD/TMX manager. 3. Fixed an issue that could prevent the RTD/TMX manager from being able to update the values. 4. Formatted the display of any RTD coefficients to match the format printed on RTDs. 2200 Revision 6.90 09/17 1. Improved C0 measurements in the W-2220 system. 2200 Revision 6.82 09/17 1. Corrected and finalized support for 64 position TMX measurements for the W-2220. 2200 Revision 6.81 09/17 1. Improved 64 position TMX measurement algorithm for the W-2220. 2200 Revision 6.80 09/17 1. Support 64 position TMX measurement for the W-2220. 2200 Revision 6.71 08/17 1. No user significant change. 2200 Revision 6.70 08/17 1. RTD related menu items in the W-2220 have been moved into a separate "RTD" menu. 2. Added a menu item that will show all RTD coefficients currently set for the boards in the system. 3. Added a variable in the INI file for the W-2220 system to save the RTD coefficients by board ID. This allows boards to be changed in the system without having to manually change the RTD coefficients or moving the RTD to the board being installed. 4. Added a variable in the INI file for the W-2220 system to save network calibration by board ID. This allows boards to be changed in the system without having to recalibrate. 2200 Revision 6.65 08/17 1. No user significant change. 2200 Revision 6.64 08/17 1. During multiple row calibration in the W-2220, there could be significant delays in processing at the end of each calibration step. During these delays, pressing the START button multiple times would generate multiple messages. When the next step completed, another START button message was processed and the software did not wait for the operator to move the calibration PCBs. This has been corrected. 2200 Revision 6.63 02/17 1. Fixed a bug since revision 6.59 when set temperature is "NONE". The soak could hang even with no soak specified. 2200 Revision 6.62 02/17 NOTE: It is recommended that all revisions from 6.24 to 6.61 be upgraded if using a USB to serial device for communications with the chamber. An improvement made in this revision could result in shorter run times. 1. Improved communications efficiency when using a USB to serial device. 2200 Revision 6.61 01/17 1. Run information recently added was erroneously reporting the chamber set temperature as 999. This corrects that. 2200 Revision 6.60 11/16 1. Crystal Data filter for printout selection is now being used for DLD data export. 2200 Revision 6.59 11/16 1. Corrected a bug in 6.58 setting temperature. 2. Since revision 6.55 the set temperature was not being updated during ramp to temperature and soak. This has been corrected. 2200 Revision 6.58 11/16 1. Improved chamber communication when setting temperature to address an issue during orbits. 2200 Revision 6.57 10/16 1. Fixed a bug that caused dual chamber W-2200 systems to access calibration files that were not used or needed. 2200 Revision 6.56 10/16 1. Corrected a bug in revision 6.55 that would not detect some software keys. 2200 Revision 6.55 09/16 1. In some systems, although revision 6.53 eliminated error messages and the run stopping due to chamber communication errors, the run was slower due to chamber communications timeouts. This version solves that issue. 2200 Revision 6.54 09/16 1. Last version did not work with older parallel port software keys. This solves that problem. 2200 Revision 6.53 09/16 1. Made chamber communication more robust. 2. Corrected a problem with new software keys reporting 6241 error. 2200 Revision 6.52 03/16 1. Lists of variables in the INI files (including the 250B), now have a new variable so that the number of items shown in a list can be reduced. This version of the W-2200 supports that new variable. 2. This release includes a revision of the 250B that fixed a bug that would generate an erroneous error message when the calibration range for a fixture did not include the C0 frequency. 2200 Revision 6.51 02/16 1. Support the latest 250B QCC file version. 2. Support new S&A PCIe TTL I/O card. 2200 Revision 6.50 02/16 1. Support the new S&A PCIe TTL I/O card. 2200 Revision 6.42 02/16 1. Corrected a problem with database updates on older versions of the 250B QCC files. 2200 Revision 6.41 04/15 1. Corrected the reported output power levels in uW for the DLD sweep on a reflection fixture (specifically the W-2220). Affects the DLDP test type and the new DLD Data export feature. 2200 Revision 6.40 03/15 Release B: Updates to the latest 250B to eliminate an unnecessary file name prompt after calibration in a W-2220 in some cases. 1. This W-2220 will now support making setup file parameter measurements at different temperatures. 2. Added a DLD Data export to CSV (comma-separated values). 3. Corrected a problem since revision 6.24, on Windows 98 PC is the chamber is connected via RS-232. 2200 Revision 6.31 03/15 NOTE: If you are running revision 6.26 or higher, it is highly recommended that you upgrade to this revision. 1. Modified the way the hardware was accessed to eliminate a possible license failure. 2. The RTD and RTDT test types in setup file parameters could have displayed DMM errors since revision 6.14 if both RTD and TMX were being measured. 2200 Revision 6.30 01/15 1. Modified software so that W-2220 can measure lower frequency crystals. 2200 Revision 6.26 01/15 1. Changed the Show RTD/TMX dialog so that it better handles systems where some of the sensors are missing. 2200 Revision 6.25 12/14 1. Improved measurements for W-2220 RFHS and HSO test types. 2200 Revision 6.24 12/14 1. Fixed a bug introducdd in revision 6.23 that prevented printing or previewing. 2. Modified the way the test for the 250B NVRAM revision was done in order to try to address an issue on one PC. 3. Now turning on raw output in the RTDTMXMgr when raw output is enabled. 4. Reduced the amount of processor usage by the W-2200. 2200 Revision 6.23 12/14 1. Fixed an error since revision 6.20 that could cause a error if setting to internal standard with an OCXO option 250B. 2. Modified File New to generate an appropriate default RUN file when running as a W-2220 system. 2200 Revision 6.22 11/14 1. New 250B and 250B DLL. 2. New RTD TMX Mgr. 3. Corrected a problem that could cause a stack overrun when using the HSO test type on a part that was dead throughout the entire run. 2200 Revision 6.21 11/14 1. Corrected phase tracking to improve measurements in W-2220 systems. 2200 Revision 6.20 10/14 1. Added support for the OCXO option. 2200 Revision 6.15 10/14 1. Improved measurements when phase tracking is enabled. 2200 Revision 6.14 07/14 1. Fixed the way the recently used file list was generated and used. 2. Modified the RTD and TMX measurement algorithm and control of the orbit command to improve W-2220 measurements on TMX parts. 3. Corrected another problem with limited print ranges on a system using the TC-100 chamber. 2200 Revision 6.13 06/14 1. Corrected a problem with limited print ranges on a system using the TC-100 chamber. 2200 Revision 6.12 06/14 1. Corrected handling of configurations for the TC-100 with partial rows used. 2200 Revision 6.11 06/14 1. Corrected an issue with the TC-100 and configurations that only used Row B. 2200 Revision 6.10 06/14 1. Add resistance reading on TC-100 chamber checkout. 2200 Revision 6.09 05/14 1. Last revision would cause an error doing an orbit with a return offset. 2200 Revision 6.08 05/14 1. Added C0-0, DLD2RAW, DLDD, DLDDR, DLDDS, FDLD1, and FDLD2 test types to catch up with latest 250B. This added support for DLD sweep even if part is dead. 2. Made changes to way chamber communication is handled to prevent temperature setting errors during step to temperature table lines. 2200 Revision 6.07 11/13 1. Added SSMAXP test type which reports the maximum phase found within a spur sweep. 2. On the W-2220, the options dialog box now correctly displays the setup file parameters FL mode setting for rows E, F, G, and H. 2200 Revision 6.06 09/13 1. Since revision 5.80, on W-2220, Row H of calibration info was not output on run info if all ports on Row H were calibrated on the same day. 2200 Revision 6.05 08/13 1. Fixed a bug that might cause the temperature range on a temperature plot to be less than needed to show the entire range. 2. Includes a new Crystal Tabular Plots report that fixed a bug where data would be shown in the last two columns even if a part was not being printed. 2200 Revision 6.04 07/13 1) Fixed a problem where temperature table processing would end on chamber retry. 2200 Revision 6.03 07/13 1) Bug since revision 5.94 could cause a problem with port switching on dual chamber systems. 2200 Revision 6.02 06/13 1) Fixed a bug since revision 5.50 causing the TC-100 chamber to go to the wrong position on Row B. 2200 Revision 6.01 06/13 1) DLDH3 test type should have been in percent. 2200 Revision 6.00 06/13 1. Added DLD10 ((MaxDLD - MinDLD) / MinDLD) and DLDH3 (Hysteresis (MaxR - MinR) / MinR) test types. 2. DLD1, DLD5, and DLD6 would indicate an error for missing LastR or MaxR even though they weren't missing when printing from an old RUN. If the printout was done at the end of a run, this error would not occur. This has been a bug since revision 4.40. 2200 Revision 5.97 06/13 1. Fixed problem that was causing the application to close after pallet ID entry. 2200 Revision 5.96 06/13 1. Support latest 250B QCC revision. 2200 Revision 5.95 05/13 1. Fixed problems with dual chamber systems that involved lock up or unable to close. 2200 Revision 5.94 04/13 1. For the W-2220 system, added the ability to specify a board ID at the start of the run for each DUT PCB. This is selected in the INI file. The Pallet IDs and Board IDs will then be added to the Unload.INI file if one is generated. 2. Corrected a problem when resuming a run at a Step To Temperature table line. In some cases the starting temperature was not always getting set correctly. 3. Added a return temperature offset for the orbit action in the temperature table. 4. Now showing another decimal place on frequency and resistance on the data display. 5. RTD/TMX manager now supports both RTD and TMX measurements at the same time during a run (W-2220). 2200 Revision 5.93 03/13 1. Changes made in revision 5.90 caused a problem with the HSO test types. Corrected this. 2200 Revision 5.92 03/13 1. Slew to temperature was storing the target set temperature rather than the "slewing" set temperature. Changed to track the set temperature during the slew instead. 2200 Revision 5.91 03/13 1. No user significant change. 2200 Revision 5.90 01/13 1. Improved chamber communication in W-2220 systems to prevent reported temperatures (actual and set) from not updating. 2. On W-2220 systems, added a miscellaneous menu selection to show the current RTD and/or TMX readings in a dialog box for troubleshooting. 3. No longer shut down chamber at end of run unless the chamber set temperature was changed by the run. 4. Added HSOM and HSOMT test types. 5. Added dOhms to R/T test type. 6. Now supports orbits that stretch across a number of table lines. 7. Added the ability to set the slew rate in set, step, and orbit temperature table actions. 8. On W-2220 systems, if calibration is cancelled after some board calibrations are completed, the software now alerts the operator and allow them to be saved. 9. Added Select All to calibrate dialog on W-2220. 2200 Revision 5.81 01/13 Release B: 250B now measures RTD temperature and TMX resistance. 1. RTD Calibration dialog was not popping to the top display in revision 5.80. 2200 Revision 5.80 01/13 1. Fixed a communication problem with the TC-100 chamber that made it slow. 2. Corrected a problem with the most recently used list that would sometimes prevent the selection from working. 3. Started using the new RTD TMX Manager for RTD and TMX resistance measurements. 4. Added raw output for some post-processed data. 5. Added TMX Resistance option for crystal data and for HSO and RFHS tests. 6. Added option to clear all temperature table line numbers if selecting printout data by table line. 7. Added the ability to show more lines in the temperature table selection box. 8. Added an orbit action for the temperature table. It works just like a Step to temperature except it also steps back to the original temperature. 9. Added an F/TMX option for data graphs (similar to F/RTD). 10. Supports Z test type and new DLD step delay and DLD step average features. 11. Fixed the spur sweep test types so that it would no longer return no spur if the sweep started within 10 ppm of resonance. 12. Modified RFHS and RFHST to calculate between every other point instead of every point. 2200 Revision 5.75 10/12 1. Added an option for Thermistor Coefficients to the RTD INI file when using an RTD or Thermistor for temperature. This new option uses Steinhart-Hart polynomial equations. 2. Added the ability to set the minimum and maximum RTD or Thermistor values in the RTD INI file instead of being fixed at 5 KOhms. 3. Improved the speed or F/R Only measurements. This was a problem since revision 5.70. 4. Removed the requirement for a Stability Slope Array to be defined for the test types HSO and HSOT. 2200 Revision 5.74 09/12 1. Fixed a bug since revision 5.70 that caused tabular reports to always show F/C0 data. Revision 5.70 of the W-2200 software added the ability to set the temperature range for many post-processed test types based on the temperature table line number. This change affected 48 of the 74 post-processed test types. All of these test types were tested before this release, however it is recommended that the results of any post process test types that use restricted temperature ranges or the GROUP test type be double-checked after installing this upgrade. 2200 Revision 5.73 09/12 1. Fixed a bug since revision 5.70 that would export 0.0 for fFrequencyPPM in crystal data reports. 2200 Revision 5.72 09/12 1. Since revision 5.50, 4350 chambers were getting turned off instead of shut down at the end of the run. This was preventing the 45 degree warm up/cool down. 2200 Revision 5.71 09/12 1. Found and fixed a bug that would sometimes cause an error in the value determined for the test type HSO that was introduced in revision 5.70. 2200 Revision 5.70 08/12 Release B: Corrects 250B revision. 1. Support new test types RFSS, RFSST, RFHS, RFHST, HSO, and HSOT for W-2220 TCXO testing. 2. Modified the Calibrate RTD screen for the W-2220 so that the coefficients are shown as a quick check. It also shows the calibrated temperature for the same reason. 3. Added the ability to show F/RTD (frequency and RTD temperature) on a crystal tabular report and on the data graph. 4. Corrected a problem using RTD-based temperature in the W-2220 when using Step to Temperature. 5. Corrected a problem with the RTD INI files for the W-2220. 6. The reports Crystal Tabular and Crystal Curvefit Tabular were updated. The first two to support the new F/RTD option. 7. Enhanced the display of the temperature table line selection in edit printout. In some cases, scrolling would prevent the last line from being shown or selected. 2200 Revision 5.64 08/12 1) Revision 5.60 reduced the communication timeout on chambers. This could cause an error to appear on dual chamber systems when raising or lowering the chamber cover and could cause a problem when one chamber was moving to reference when the other was not. This timeout has been restored to the original setting. 2200 Revision 5.63 08/12 1. Fixed a problem that affected Calculated FL and "Measure F/R Only" when using Physical Load. This problem occurred if the crystal measured Dead on the first temperature in the run and affected the calculated frequency. 2200 Revision 5.62 08/12 1. On W-2220 systems with the DMM installed to measure RTDs, fixed a problem in the last revision when calibrating via the 250B that could cause the DMM to beep. 2200 Revision 5.61 07/12 1. Added back support for 4310 (benchtop) and TC-100 chambers missing since revision 5.50. 2. Fixed a problem with the 10-point table lookup for RTD temperature conversion. 3. Added INI variable for DMM to be able to set the range to a fixed range. RTD needs to be in a fixed range to be accurate. 4. Fixed a bug that occurred at startup when running on a dual chamber system. 5. Fixed a bug since revision 5.41 when running on a dual chamber system that could corrupt the database. 6. Fixed a bug at startup on some chamber configurations giving an incorrect error prompt. 2200 Revision 5.60 07/12 THIS RELEASE NOT FOR USE WITH BENCHTOP SYSTEMS OR TC-100 CHAMBERS 1. Improved communication with chamber from previous release. 2. Improved handling of chamber when using long slew times. 3. Added code to detect and correct a chamber off condition at every part. 4. Added additional information to the run file concerning chamber status in some cases. 5. When configured for a DMM to measure RTDs, now monitors RTD values at all times and data is placed in the database, even during F/R Only and Crystal Data measurements. 6. RTD temperature is exported in Crystal Data export now. 7. The use of RTD temperature or chamber temperature is now configurable for printouts. This option is only available if the database contains at least one valid RTD temperature. 8. Reduced the number of calls to compact the database during a run to improve throughput in some cases. 9. Now compacting database during a slew to improve throughput in some cases. 10. Improved handling of a shared COM port (DMM for RTD). 11. Fixed a bug in the last revision that caused the W-2200 to think the chamber was OFF in serial mode when set point was 0.0 C. 12. Added the ability to select the RTD temperature for the data graph display instead of chamber temperature. 13. Added code to warn user about possible INI setting conflict between rows in chamber and chamber model. 14. In the event the INI file is set with the wrong number of rows, calibrate fixture will now have the select button disabled in the W-2220. 2200 Revision 5.50 06/12 THIS RELEASE NOT FOR USE WITH BENCHTOP SYSTEMS OR TC-100 CHAMBERS 1. Improved look and feel. 2. Fixed a bug with printout selection by temperature table number in some cases. 3. TC-100 supported in this revision. 4. Benchtop chambers (4310) not supported in this revision. 2200 Revision 5.42 05/12 1. Fixed a bug since revision 4.14, where DLD1, DLD5, and DLD6 would not calculate the correct limits. 2200 Revision 5.41 05/12 1. In some very rare cases, determination of turning point and inflection points could cause the print manager to lock up. This has been corrected. 04/12 1. Added support for up to 6th order curvefit. 2. Added curvefit test types CF0, CF1, CF2, CF3, CF4, CF5, and CF6 to allow the operator to specify a different temperature offset than 26 C. 3. Added test type RTD and RTDT. This will read the value of an RTD via a DMM. RTD is resistance and RTDT is temperature. For temperature, RTD.INI file entries specify S&A coefficients, ITS-90 coefficients, or a table of up to ten points with linear interpolation. 2200 Revision 5.31 02/12 1. Corrected a display problem that occurred when configuring printouts. If there were no plots on the selected printout and the measurement selection was set to temperature table line, the group box would drop below the bottom of the dialog box and the OK button would not be visible. 2200 Revision 5.30 01/12 1. Revision 5.10 changed the folder selector dialog to a tree structure. This has now been replaced with an Explorer dialog so that shortcuts and network drives are accessible again. This also allows use of tools to create new folders and rename folders. 2. When exporting, the name of the file would truncate the run name at the first period encountered. This has been corrected so that the entire run name is used. 3. Since revision 5.10, if the run name changed, the exported file name did not and the export would be done to the old run name. This has been corrected. 4. Changed the format for export file name when run name plus report name is selected. Now, the report name will be surrounded by (). 5. Made a change to help prevent corruption of the database when saving. 6. Allow description field change even when "Allow Editing" is false. 7. Includes a new Excel Export Setup File Parameters report that will show test type labels if they were entered. Previous revisions showed only internal test names. 8. Includes a new Excel Export Setup File Parameters report that will suppress output on test types that are not configured. Previous revisions exported NO_VALUE for all 30 fields. 9. If the export folder created when the run was configured no longer exists, an error message is now displayed and the export is halted. Previous revisions would attempt to export and an error would be generated and the print manager would terminate. This would require a restart of the W-2200 for further printing or exporting. 2200 Revision 5.22 12/11 1. Corrected a problem on systems using a TC-100 chamber. Now a single configuration group can include parts on both rows. Previous revisions would close when the run was started. 2. When slewing to temperature and using timed measurements, entry can now be made in hours, minutes, and seconds instead of just minutes. 2200 Revision 5.21 11/11 1. Corrected a problem where the W-2220 could stop and report Stop On Retry. 2. Fixed Edit printout dialog not sizing correctly if the report did not involve a plot (e.g. Setup File Parameters). 2200 Revision 5.20 10/11 1. Added the ability to select measurements to include in printouts by temperature table line. 2. When a limited temperature range is selected for crystal data in the edit printout dialog, since revision 3.61, the selected temperatures would not show when displaying the dialog box again. Corrected this. 2200 Revision 5.11 10/11 1. Now supports physical load on benchtop systems with two positions. 2. Added prompts for installation of a short and removal of the short during physical load measurements so that the run won't continue until the crystal is back in place on the systems that require a manual measurement of the physical load. 3. Only measures physical load if the row is used by the run. 4. Only displays the FL method for the number of rows configured for the chamber. 5. Added a menu entry for the chamber manual PDF. 2200 Revision 5.10 08/11 1. File export now uses a tree selector for the folder. 2. File export now has two options the file name: original (run name) or run name + report name. This allows multiple report exports in a single run without overwriting. 3. Now uses a tree selector for directory selection in Edit Configuration and Edit Printout dialogs. 2200 Revision 5.00 07/11 Release D: Corrects 250B power calibration. 1. Initial W-2220 release. 2. Support new Reflection fixture type for W-2220. 2200 Revision 4.92 06/11 RELEASE C: Due to a 250B calibration file error, revision 12.23, 12.24, 12.25, and 12.26 of the 250B MUST upgrade. 1. If measuring a single column of parts (or one part), this revision will not reference the wheel after measuring the part(s). This makes measurements occur closer together in time and does not wear on the wipers. 2. Better regulated communication with the chamber to try to solve a problem with the TC-100. 2200 Revision 4.91 06/11 1. Because the location of different dialog boxes is saved and restored for user preference, it is possible when changing monitor size/resolution or switching from multiple displays to a single display for these dialog boxes to not be visible. Added code at startup to check for this possibility and move the saved dialog positions into view. 2. If "Use Chamber" is set to no/false in the INI, but the chamber is a TC-100, was still attempting to communicate. Corrected this. 3. The TC-100 chamber would not start at the correct wheel position if the configuration started on Row B at any position other than position 1. Corrected this. 2200 Revision 4.90 03/11 1. Adds support for Wide (Nonlinear Crystal) sweep. 2. Adds support for Fast sweep. 3. Adds support for Narrow (Single Port) sweep using Narrow sweep technique. 4. Made frequency measurement faster in some cases. 5. Improved DLD measurement in some cases. 6. Since the end of 2008, the 250B and the W-2200 have had separate frequency calibration files. That meant that, unless both were calibrated at the same time, frequency measurements may not correlate. This version now uses the same file as the 250B. 2200 Revision 4.84 02/11 1. Updated to new 250B database revision. 2200 Revision 4.83 02/11 1. For W-2200i, improved error information on display. 2. Improved Fr determined by Narrow sweep. 2200 Revision 4.82 10/10 1 Fixed a problem with printing or exporting with the SN test type configured. 2200 Revision 4.81 08/10 1 Since revision 4.70, if a dead crystal was encountered during a temperature run, an exception could be generated. Fixed this. 2200 Revision 4.80 07/10 1. Reduce change of transit crash or system lock up on W-2200i. 2200 Revision 4.79 05/10 1. Support latest 250B revision. 2200 Revision 4.78 05/10 1. Added INI file variable to disable measurement retries on W-2200i for speed. 2200 Revision 4.77 02/10 1. Fixed a bug since revision 4.40 that left the Operator and Description fields grayed out after a run. 2200 Revision 4.76 01/10 1. Fixed DLTR, R/AT, and R/MT to show result in "%" if selected for units. 2200 Revision 4.75 12/09 1. Fixed a bug when the new "Print All" checkbox was selected, it didn't always print all of the crystals. 2200 Revision 4.74 11/09 1. Support new 250B database revision (release 4.73D included a new 250B revision). 2. W-2200i software will not shake parts in unused chambers any more. 2200 Revision 4.73 09/09 Release D: W-2200i support new purge air valve. Release C: W-2200i added total part count to bin window. Release B: W-2200i should not use release A. 1. In W-2200i fixed a bug that generated ZEROREF. 2. In W-2200i, added contact delay before beginning calibration. 2200 Revision 4.72 09/09 Release B: Fixed a problem where some 250B cards coupled with certain crystals would report the wrong amplitude value for RF In at low amplitude levels (below -100 dBm). 1. Added a button to move transit up when an error occurs in the W-2200i. 2. In the W-2200i, the set temperature stored in the database for measurements was wrong if an offset existed. 2200 Revision 4.71 09/09 1. Improved FrOnly measurements for certain crystals. 2200 Revision 4.70 09/09 1. Printout at end of run in W-2200i was causing the program to close. 2. Added Binning Parameters to header area on W-2200i. 3. Fixed a problem with positions on the TC-100 when using only row B. 2200 Revision 4.64 09/09 1. In the W-2200i even if a chamber has a set temperature, if it has no measurement, parts will not rotate through it. 2. In the temperature table for the W-2200i, entering a space for the temperature will now result in None. 3. Made W-2200i lot change more resistant to database errors. 2200 Revision 4.63 09/09 1. Added retries per pocket to the run information table for W-2200i. 2. Made database more robust on lot change in the W-2200i. 3. Fix a bug in the W-2200i, where entrance process errors never got cleared once they occurred (like part not detected while down at entrance track). 2200 Revision 4.62 09/09 1. Added retries to Run Information table for W-2200i. 2. For W-2200i, fixed a bug in clearing two parts and restoring wheel position on confirm error. 2200 Revision 4.61 08/09 B-release corrects a problem for the W-2200i in Set Offsets (of the W-4320) for chamber motors to fix a referencing issue. 1. In W-2200i, do not clear "stop on retry" at end of lot. 2. For W-2200i, now showing position number on the chamber displays and in run information. 2200 Revision 4.60 08/09 1. Fixed a bug where if the 1st plot selection was not set to autoscale, but was the only thing plotted, it would be autoscaled anyway. 2. Added the ability to select whether the points are connected on each plot and whether or not the points are indicated with a marker on each plot. 3. Added a configuration and temperature table information field in place of the chamber status on the main view on a W-2200i. 2200 Revision 4.55 07/09 B-release includes improvement in referencing routine for W-2200i. 1. On W-2200i, when confirming continue, errors while referencing or restarting can be retried. 2200 Revision 4.54 07/09 1. On W-2200i, changed "Retries" to "Parts Retried". 2. In W-2200i when confirming continue, now allow only clearing of the parts at the chamber that has a jam instead of all parts in the system. 2200 Revision 4.53 07/09 1. This revision will not let run start if bin cover is open on W-2200i and will put up a message indicating that the cover is open. 2200 Revision 4.52 07/09 1. Show name and number of report on Progress window for print manager. 2. Added binning parameters information to start of run in Run Information for 2200i. 3. For W-2200i, support W-4320 display of possible bad pogos. 4. For W-2200i, if purging and timeout occurs, keep trying to purge and continue run if achieved. 5. Made TEMPERATURE_RECOVERY_SOAK_SECONDS an INI setting instead of a define. 6. Don't ask to turn off chambers at the end of a W-2200i run if they are already off (were never on). 7. In the W-2200i, pause all motion when an error condition generates a confirm dialog box. 8. In W-2200i, added crystal ID and position number to dialog box on stop on retry. 2200 Revision 4.51 06/09 gpc 1. Support new database revision for 250B. 2200 Revision 4.50 05/09 1. Corrected a problem where the database was missing data in the W-2200i if soaking was required due to chamber temperature out of range. 2. Added Stop On Retry feature for W-2200i. 3. Added assisted calibration for W-2200i. 4. No longer turning of purge in W-2200i at end of run if chambers are still on. 2200 Revision 4.42 04/09 1. No user significant changes. 2200 Revision 4.41 03/09 1. No user significant changes. 2200 Revision 4.40 09/08 1. Support W-2200i. 2. Added support for CL Offset from 250B INI file. 3. Fixed a bug in which pressing the minus button on the data display window when displaying A001 would skip the last part in some cases, primarily when the top row was not used. 2200 Revision 4.39 12/08 1. Support latest 250B revision. 2200 Revision 4.38 08/08 1. Support latest 250B revision. 2200 Revision 4.37 07/08 1. Added 131 position wheel to INI file default. 2. Allow curve-fit selection on crystal tabular printout if "frequency at actual" is selected because it is determined based on a curve-fit. This allows correlation between the information on this report and on other reports. 2200 Revision 4.36 04/08 1 Group determination now recognizes Dead crystal data measurements. 2200 Revision 4.35 01/08 1. Now supports a dual position W-2200 Benchtop system. 2200 Revision 4.34 10/07 1. No user significant changes. 2200 Revision 4.33 10/07 1. Support "into RR" mode for power from 250B. 2200 Revision 4.32 08/07 1. A problem in 250B revisions 9.40 through 9.50 could cause a problem with recognition of the "High Q/High Time Constant" sweep type. This revision correctly recognizes the sweep type regardless of the 250B revision used to create the QCC file imported. Recommend this upgrade for W-2200 revisions 4.22 through 4.31. 2200 Revision 4.31 08/07 1. If there are no limits on relative angle, no longer indicates an error if no relative angle can be determined. 2200 Revision 4.30 08/07 1. Added new test types: AR/T (average resistance over temperature range), MR/T (median resistance over temperature range), R/AT (worst case resistance compared to average resistance over temperature range - limits are a multiple of average resistance), R/MT (worst case resistance compared to median resistance over temperature range - limits are a multiple of median resistance). 2200 Revision 4.22 06/07 1. Supporting new 250B revision with up to 30 DLD points and new DLD resistance mode. 2. Reduced initial DLD sweep power level to reduce the impact of the initial frequency measurement on the DLD sweep measurements. Recommand all DLD users to update to this revision. 3. Modified test types like RR/T and C1/T to ignore values from Dead crystal data measurements. Dead crystal data measurements should be caught using F/T. 4. Dead crystal data measurements now return negative PPM values so a low limit will catch them. Previous revisions would return a large positive PPM value. 2200 Revision 4.21 05/07 1. It is now possible to exit the software without saving any changes to the run. 2. Made less susceptible to database errors. 3. Now clearing a potential RS-232 chamber communication error at startup to prevent an error message. 4. Opening a new run and answering yes to the prompt to save the changes to the current run will no longer cause an exception error. 2200 Revision 4.20 04/07 1. Added custom action. 2. Added high drive duty cycle. 2200 Revision 4.15 02/07 1. Last revision did not recognize the latest 250B QCC files. 2200 Revision 4.14 01/07 1. Corrected problem printing data with limits on test types DLD1, DLD5,and DLD6. The limits are calculated and the data required for the calculation was missing when printing data from a run completed at a previous time. 2200 Revision 4.13 01/07 1. Corrected problems with creation of Unload.INI. 2200 Revision 4.12 12/06 1. On some systems, a chamber error would occur at start up during database update and cause a system lock up. 2200 Revision 4.11 12/06 1. Database error at startup in revision 4.10 has been fixed. 2200 Revision 4.10 12/06 1. Fixed a problem where some crystal failures were not highlighted red in Crystal Tabular printouts. 2. Support physical load measurement for 4310 chambers. 3. SPFR is now being measured. 4. Corrected TC equation to match 250B. 5. Support reflection type test head. 6. Fixed RPP measurement. 7. Added NSPF1, NSPFR, NSPRR, and NSPUR test types. 8. Fixed a problem that slowed throughput since revision 3.87. 9. Fixed a problem that could prevent the application from ending. 2200 Revision 4.04 10/06 1. Fixed a problem with slew to temperature introduced in revision 3.87. 2200 Revision 4.03 10/06 1. Now supports 2 chamber, 4 row systems. 2200 Revision 4.02 10/06 1. Improved Measured FL repeatability over temperature. 2200 Revision 4.01 09/06 1. No user significant changes. 2200 Revision 4.00 09/06 1. Since revision 1.70, Fl measurements made over temperature using the "Physical FL" method were being compensated for the temperature coefficient of C1 in error. This caused the resulting crystal angle to be less than the correct angle measured using the "Measured FL" or "Calculated FL" methods. An example crystal angle error due to this issue was about 0.5 degrees. All physical capacitor users are recommended to upgrade to 4.00. 2200 Revision 3.87 08/06 1. Improved chamber communications. 2. Fixed problem with display of C0 in narrow mode. 3. Fixed "Measure Every X Minutes" option. 2200 Revision 3.86 07/06 1. Measuring while slewing was not updating the chamber temperature for each point. 2. It was not possible to edit the printouts on some saved old runs. This has been corrected. 2200 Revision 3.85 06/06 1. Added support for the following test types: DF DLD9 PC1 PFL PFR PL PRR SSDLDF SSMINF SSMINZ SSZ 2. Added support for Narrow Sweep mode. 2200 Revision 3.84 05/06 1. A problem with printing columns in printouts was resolved. 2200 Revision 3.83 05/06 1. Another problem with selecting rows in printouts was resolved. 2200 Revision 3.82 05/06 1. A problem with selecting rows in printouts was resolved. 2200 Revision 3.81 05/06 1. Fixed SPFR that has not worked since Revision 2.80. 2200 Revision 3.80 04/06 1. Support unloader INI file creation for 901A-based systems. 2. Save 250B calibration frequency on application exit. 2200 Revision 3.71 04/06 1. Support latest 250B database revision. 2200 Revision 3.70 03/06 1. Increased soak time entry length to support longer soak times. 2. Changed the names displayed on the buttons if the STOP button is pressed so that they are more descriptive. 3. Changed code so that when the "wait for temperature" is ended, the next step is executed as though the previous step reached temperature. 4. Allowed list edit dialog to grow in size and show more data. 5. Properly display the degrees symbol for Chinese Simplified Windows. 2200 Revision 3.68 01/06 1. Added more debounce for the 2451 relays. This is necessary with faster computers. 2. Fixed a bug in the interface for Transat chambers. 2200 Revision 3.67 01/06 1. Revision 3.66 introduced a timing problem that would allow the software to measure before the wheel had stopped moving. Corrected this. 2200 Revision 3.66 01/06 1. Due to increased speed of computers, the S&A 4210 was unable to keep up with the polling rate. Slowed down polling of chambers to support 4210. 2200 Revision 3.65 12/05 1. No user significant changes. 2200 Revision 3.64 12/05 1. Remember the settings for all file open and save dialogs. 2. Properly implemented C0 Offset from 250B INI file. 2200 Revision 3.63 12/05 1. A bug caused the software to assume the presence of the S&A 2451 when it was not used. Corrected this. 2. Now numerically sorting the list of available wheels. 2200 Revision 3.62 12/05 1. Code added in revision 3.61 to detect a read-only file caused a problem if file didn't exist. This was corrected. 2200 Revision 3.61 12/05 1. Measurement interval now supports fractions of minutes. 2. Added more plot points to the Data Graph. 3. Changes made to improve throughput of system. 4. Displaying a more descriptive error when encountering a read-only file. 2200 Revision 3.60 09/05 1. Allow user selection of plot axis colors. 2. Added a Maximum Slew rate entry to 2200 ini file. 3. Support Visual Basic reference to the W-2200 as an OLE server. 2200 Revision 3.50 08/05 1. Added support for the new 4310 temperature chamber. 2200 Revision 3.44 08/05 1. No user significant changes. 2200 Revision 3.43 08/05 1. No user significant changes. 2200 Revision 3.42 08/05 1. Physical load measurements were failing due to changes to the 250B INI file variables. Corrected this. 2200 Revision 3.41 08/05 1. In some cases, Print and Preview were crashing. Corrected this problem. 2200 Revision 3.40 07/05 gpc 1. Added support for a DLD analysis range. 2. Added the test type HDRV to high drive the crystal (special test head may be required). 3. Added the test type DLD8 (MinRR / RR). 4. Added the test types Ref CL and Ref FR so those values can be shown on certain printouts. 5. Added support for a 52 Position Wheel. 2200 Revision 3.34 07/05 1. Fixed group number displays. 2200 Revision 3.33 05/05 1. In some cases, revision 3.32 would hang up trying to update the 250B file. This has been corrected. 2200 Revision 3.32 05/05 1. More changes to support new INI file variables in the 250B. 2200 Revision 3.31 05/05 gpc 1. Support new INI files for 250B. 2200 Revision 3.30 04/05 1. Fixed a problem with the reports from revision 3.20. 2. Added INI file entry to control internal reference tracking. 3. Showing repeat counter in status. 2200 Revision 3.20 04/05 gpc 1. Now using set temperature instead of actual temperature for temperature range on test type. 2. Added the test types DLDH2R (resistance delta for maximum hysteresis), FCF/T (frequency of curve fit over temperature), and SN (serial number). 3. Can now view Data Graph frequency in ppm. 4. Added internal reference tracking. 2200 Revision 3.10 01/05 1. A bug since revision 2.90 caused the wrong values to be displayed for Crystal Data and FR Only measurements when the units were not "standard". 2. Improved graphing. 3. Corrected a problem with test types using PPM referenced measured FR and Measured FR*3. 4. Added PPM reference to Measured Fl and Measured FL*3. 5. Added test type Rpp for pin-to-pin resistance. 6. Added PDF export.